C. Connecting Vent Pipe

Reference instructions in the termination kit.

• Install the 3-inch fl exible vent pipe(s) down through the

chimney.

• Secure the exhaust fl exible vent pipe to the 3 foot section

stainless steel flexible vent pipe using the factory-
installed 3-inch collar in the stainless steel section of
pipe (see Figure 8.1).

• Secure the stainless fl exible vent pipe to the exhaust

starting collar on top of the appliance with three screws
and seal with stove cement rated for continuous
exposure to 1200ºF or higher.

• Use 3 screws to attach the section of inlet air vent to

the inlet collar on the collar slide plate and seal with
stove cement rated for continuous exposure to 1200ºF
or higher. See Figure 8.1. NOTE: The collar slide plate
may be removed from appliance to aid installation.

Figure 8.2

CUT AND BEND

FLASHING AS NEEDED

TO FIT CHIMNEY

SEALANT

ADHESIVE

• Trim chimney top plate to minimize excess overhang or

bend over fl ue tile (see Figure 8.2).

• Place 3/8 inch bead of 300ºF silicone on fl ue tile top.

Advertising