Electrical information, A. wiring requirements, B. intellifire plus – Heat & Glo Fireplace HEAT & GLO ESCAPE-I35-C User Manual

Page 28: Ignition system wiring

Advertising
background image

Heat & Glo • Escape-I35-C, Escape-I30-C • 2201-901 Rev. K • 1/13

28

A. Wiring Requirements

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the Canadian Electric
Code CSA C22.1.

• This appliance comes with a 110-120 VAC cord

assembly. This is required for proper operation of the
appliance (Intellifi re Plus

TM

Ignition). An outlet box may

be installed in a bottom back corner of the existing solid
fuel masonry or factory built fi replace to plug in the cord
assembly, or the supplied power cord may be routed out
onto the hearth to a nearby outlet.

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in compliance
with the applicable electrical codes, when it is installed in
locations such as in bathrooms or near sinks.

• Low voltage and 110-120 VAC voltage cannot be shared

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.

10

10

Electrical Information

B. IntelliFire Plus

TM

Ignition System Wiring

• Wire an outlet box (110-120 VAC) in the bottom back

corner of the existing solid fuel masonry or factory built
fi replace to plug in the cord assembly, or the supplied
cord assembly may be rerouted out onto the hearth to a
nearby outlet for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.

• Refer to Figure 10.1, IPI Wiring Diagram.

• This appliance is equipped with an IntelliFire Plus

TM

control valve which operates on a 6 volt system.

• Plug the 6 volt transformer plug into the appliance cord

assembly to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery tray before use.
See Section 2.H for instructions on locating battery tray
and installing batteries.

• Battery longevity and performance will be affected by

the service temperatures of this appliance. Batteries
should only be used as a power source in the event of an
emergency such as an outage.

Figure 10.1 IPI Wiring Diagram

AUX WIRE EXTENSION

LIGHT WIRE ASSEMBLY

OPTIONAL

TO CORD ASSEMBLY

120VAC

AUX 300

MODULE

AUX1 AUX2

FAN

BATTERY PACK

6V DC (AA X 4)

ACCENT SOCKETS (2)

EMBER BULB 50W (2)

ORANGE

(PILOT)

GREEN

(MAIN)

TO CORD ASSEMBLY

120VAC

MODULE

ORG

WHT

INTERMITTENT PILOT IGNITOR

BLACK

RED

AUX2 NOT USED FOR INSERT MODELS.
PROTECTIVE COVER INCLUDED.

RC300 4.5V DC
(AAA X 3)

MODULE RESET

SWITCH

WIRE ASSEMBLY

NOTE: SEE FIGURE 10.3 FOR ADDITIONAL INFORMATION

EMC FILTER UNIT

BROWN

GROUND