5

Using a 1/2” deep well socket loosen the nut that

was under the exhaust cover plate until it is flush

with the end of the threads. Pull the exhaust clamp

down from notch in firebox top. Lift the clamp

assembly up and disconnect it from the intake /

exhaust adapter.
Remove exhaust adapter from the top of the stove

assembly being careful not to damage the sealing

gasket.

Determine the flue restrictor needed for this

application and install into the exhaust pipe on the

stove adapter.

Propane uses the 2” ID restrictor for 10’ to 16’ and

the 1.75” ID for the 16’ to 36’ chimneys.

Natural gas uses no restrictor from 10’ to 16’ and

the 1.75” restrictor from 16’ to 36’.

6

7

8

Lay cardboard or an old cloth onto the fireplace

hearth to keep from damaging it. If the pipe adapter

has been removed from the stove body connect the

flex pipes to the intake/exhaust adapter assembly,

be sure to use the correct pipe on the exhaust

connector, the one that was marked with paint

earlier. Tie a string to the exhaust adapter so you

can pull the adapter onto stove body.

Check stove to opening side clearance. If there is

not enough room to reach beside stove while it is

installed you may want to remove the gas line from

the valve assembly and connect it to your supply

line inside the fireplace first, then reconnect to the

gas valve.
Set stove into fireplace opening. Connect the pipe

adapter or flex liners to the stove. To reconnect

the pipe adapter use the string or reach through

the exhaust passage and pull the adapter onto

the stove body. While looking through the center

exhaust port located toward the front of the firebox,

connect the “J“ bolt to the adapter. Next slide the

clamping adapter into the notch in the firebox

top and tighten the nut. Remove the string when

completed.

The flue restrictor can be installed after flex pipes

are connected and stove is in fireplace opening.

To change or install restrictor remove glass door

then remove log . Next remove screw, washer and

spacer in the rear brick panel and remove the brick

panel while holding relief door open with one hand.

Remove the 2 screws holding the exhaust cover

onto the rear of the firebox.
To remove a restrictor push the front of the plate

upward and pull down on the rear side bringing it

into the firebox.
To install a restrictor, hold plate vertically and slide

up into exhaust connector through the back of the

firebox. Push bottom of plate back allowing it to set

onto lip inside the exhaust adapter.

Flue

Restrictor

Look through to connect “J” bolt.