Maintenance – Harman Stove Company XL User Manual

Page 25

Advertising
background image

Maintenance

Removing the Glass Door
Remove door by pulling latches out as shown and pulling

the bottom of the door out from the unit about 3 inches.

Then lift the door slightly up and off the hooks.

Replacing the Glass and Gasket
The ShadowLight XL uses part no. 3-44-00539

fiberglass gasket in the front door. Should it ever need

replacement, use only the proper replacement gasket

that is available from your Harman dealer. To replace

the gasket, follow this procedure.
1. Lay glass front face down.
2. Bend the four tabs up far enough to remove the

glass.
3. Remove glass from frame. Discard gasket.
4. Install new gasket around glass (thick side toward

stove).
5. Place glass in frame.
6. Bend tabs to secure glass. Not too tight.
7. Reinstall glass door by placing the door on the hooks

at the top of the opening as shown. swing the bottom of

the door in to the unit. Close the two latches to secure

the door.
Cleaning the Glass
The glass may be cleaned with ordinary household glass

cleaner and a soft cloth or paper towel.
WARNING: Never clean the glass when it is hot. Do not

use abrasive cleaners on the glass.

Inspecting the Venting
An inspection of both pipes of the venting system

should be made during the annual service appointment.

They must have no blockage and be in good condition.

The vent manufacturer’s instructions may provide

specific suggestions or details on vent inspection. Any

sections that are taken apart for the inspection must be

reassembled and sealed as required.

Cleaning the Log Set and Firebox
During the annual inspection and maintenance

appointment, the service person should clean dust, lint,

and any light accumulation from the logs and the firebox

area. An extra-soft brush should be used on the logs as

they are extremely fragile; a vacuum cleaner may be

used on the firebox. If at any time the logs cannot be

removed or installed without forcing, the cause must be

found. The logs must never be forced.

A qualified service technician recommended by your

Harman dealer should conduct an annual inspection

and maintenance of your fireplace, its venting, and

the installation to keep it running safely and efficiently.

The following procedures should be performed only

by a qualified service person. The gas supply should

be turned off whenever a maintenance procedure is

performed.
If the glass front, or front access door are removed for

servicing, they must be replaced prior to operating the

fireplace.

WARNING: DO NOT OPERATE THIS

APPLIANCE WITH THE GLASS FRONT

REMOVED, CRACKED OR BROKEN.

REPLACEMENT OF GLASS SHOULD BE

DONE BY A LICENSED OR QUALIFIED

SERVICE PERSON. NEVER USE SUBSTITUTE

MATERIALS.

DO NOT STRIKE OR SLAM GLASS.

25