Installation – Harman Stove Company XL User Manual

Page 24

Advertising
background image

Installation

Only For Qualified Installers

Connecting the

Optional Thermostat

If the optional thermostat is used, it must be plugged into

the terminal strip located in the lower left front corner

of the heater.
When installing a millivolt control system, use only a

special low resistance thermostat. DO NOT USE A

REGULAR HEATING THERMOSTAT.
Be sure that all electrical connections are clean, free from

corrosion, and tight. Inspect connections periodically to

confirm that no corrosion has built up over time.
When properly installed and maintained, a millivolt

control system should give many years of trouble-free

service.
It is important to use the proper gauge wire for the

length used.

RECOMMENDED WIRE GAUGES

Maximum

Wire

Length

Gauge

100’

14

60’

16

40’

18

25’

20

15’

22

Thermostat

Remote Control
The button on the remote control can be used to turn

the burner on and off.
This remote uses an ultrasonic control method and does

not need to be pointed directly at the fireplace.
A hand held sending unit, receiving unit, mounting

bracket and all wiring are included when you order the

remote control.
Installation instructions are packed with remote kit.