68 Hayes ADSL Ethernet User’s Guide

Monitor period

Sets the Monitor Interval shown on the

System Status page.
The default is 60 seconds. Type a new value

in seconds.

Enable CRC

History

1 = Displays error counts in the CRC

History box below.
0 (the default) = Disables error count

display.

CRC Monitor
Period 1

Sets the first sample period for the CRC
error count displayed in the box below.
The default is 15 minutes. Type a new value

in minutes.

CRC Monitor

Period 2

The second sample period for the CRC

error count displayed in the box below.
The default is 24 hours. Type a new value

in hours.

Click Update to refresh the display.
The CRC History box displays the errors of each 15-minute

period, for the past 1500 minutes. You can adjust the 15-minute

period in the CRC Monitor Period 1 field described above. Note:

a maximum of 100 intervals are recorded and the 1500 minutes
value is therefore dependent on the interval time used.
To enable the display of CRC history, you must set the Enable

CRC History parameter to 1.