Chapter 6: Call Detail Recording

Establish connection between Tenor CMS and CDR Server

In order to capture CDRs, a connection between the Tenor CMS unit and the CDR server must be established.
A Tenor CMS can be configure to connect up to four CDR servers via port 9002, 9003, 9004, and 9005. Based
on configuration, the Tenor CMS unit can either establish a TCP/IP session with one or both of these CDR
servers. A flow diagram (Figure 6-1) illustrates the general transfer of information.

Figure 6-1 Flow of CDR Information

Before attempting to collect CDRs, you should configure the desired information. Through CLI commands,
you can assign CDR server IP address, CDR server port number and CDR server password information using
the following CLI commands: cdrserverip, cdserverport, cdrpassword, and cdrformat.

CDRServerIPAddr: IP address of the CDR server. (Used when the Tenor CMS unit established connec-
tion with the CDR server.)

CDRServerPort: The application port numbers used by the CDRServer(s) CDRServer(s). (Used when
the CMS establishes connection with CDR server.)

CDRPassWord: Password to be used by the CDR server(s).

CDRFormat: This configuration parameter command is used to choose which of the possible Call Data
Record output formats you would like to send to your CDR Server: Standard, Standard with session ID
functionality, Extended, Extended with session ID functionality, or Extended with Incoming Slot/Device
information. Possible entries are 0 (standard format), 1 (extended format), 3 (extended CMS format), 4
(extended CMS format with session ID), 100 (standard format with session ID functionality), 101
(extended format with session ID functionality), 103 (extended CMS format with session ID functional-
ity), 104 (extended CMS format with session ID functionality).

Tenor CMS

CDR Server

Tenor CMS connects

to CDR Server automatically.

(after initial configuration of

S erver IP Address & Port Number)

or

CDR Server logs into Tenor CMS'

Port Number 9002 or 9003

TCP/IP Connection Established

Sends Welcome Message

Sends Password Prompt

Enters Password

Verifies Password

Provides CMS' IP address &

U nit N ame

Provides last CDR Sequence

Number received

Begins delivering CDR's