Venting, 6 installing into an existing fireplace chimney, 7 installing into an existing chimney – Harman Stove Company P43 User Manual

Page 12

Advertising
background image

1

P43 Pellet Stove

#6 Installing into an existing fireplace

chimney

This method provides excellent venting for

normal operation. This method also provides natural

draft in the event of a power failure.

In some places in the US and Canada it is re-

quired that the vent pipe extend all the way to the top

of the chimney. The pipe or liner inside the chimney

should be 4"diameter.

In this method a cap should also be installed

on the chimney to keep out rain. Be sure to use ap-

proved pellet vent pipe fittings. Seal pipe joints with

silicone or aluminum tape in addition to the sealing

system used by the manufacturer. Pipe size should

be increased to 4" using this method.

#7 installing into an existing

chimney

This method provides excellent venting for

normal operation. This method also provides natural

draft in the event of a power failure.

In some places in the US and Canada it is re-

quired that the vent pipe extend all the way to the top

of the chimney. The pipe or liner inside the chimney

should be 4"diameter.

In this method a cap should also be installed

on the chimney to keep out rain.

Fig. 12

Fig. 13

venting