P43 Pellet Stove

P43 autOMatic ignitiOn eSP cOntrOl

Feed adjuster

Sets the maximum

feed rate

Test

Runs all motors at full

speed for one minute to

check operation. After

two minutes the stove

will go to minimum burn

and the blowers will

alternate from high to

low every minute to

remind you that you are

still in "Test Mode".

Igniter switch

Set to appropriate

Start-Up mode.

Distribution Blower

s p e e d a d j u s t m e n t

range.

L = low

H = high

V a r i a b l e s p e e d

anywhere between L

and H; although as the

stove temp. goes up ,

so does the low end of

the scale.

Temp dial

Allows you to adjust the room temperature in Room

Temp Mode using the outer scale marked in degrees

Fahrenheit. It also allows you to adjust the stove

temperature while in Stove Temp Mode using the inner

scale marked from 1 to 7.

Mode Selector

Allows you to choose between

Room Temp Mode, Stove Temp

Mode, or OFF. Also allows you

to vary the distribution blower

speed by turning the knob to

the high or low side of each

mode.

Power Light

Indicates power to the

control.

Indicates power to the

feed motor.

Indicates power to the

igniter

Indicates power to

combustion blower

Status Light

Will be lit in either stove

or room temp mode

when pointer is not

within off position band

except after normal shut

down. Blinks to indicate

errors listed below.

Indicates power to

distribution blower.

Status light error messages:

1 blink: Indicates control board self diagnostic fail-

ure. This requires a manual reset*.

3 blinks: Indicates ESP (Exhaust Sensing Probe)

failure. This requires a manual reset*.

4 blinks: Can occur only in Room Temp Mode and

indicates Room Sensing Probe failed or not installed.

If a Room Sensing Probe is then installed, the status

light will automatically reset.

5 blinks (in igniter auto. Mode Only): Indicates

that the unit has failed to light within the 36 minute

start cycle. To reset - Turn Mode Selector to "OFF",

then turn to either mode again.

6 blinks : Indicates that the control has calculated

poor or incomplete combustion occurring for more

than 50 minutes.

A six blink status may be set if the stove is allowed

to run out of pellets. To reset, turn mode selector to

"OFF" then back on to the desired mode. If the unit

was not out of pellets, see Troubleshooting section,

Page 6, for more details.

* Manual reset- disconnect power cord for a few

seconds and reconnect. If error still occurs call your

Dealer.

Dealer Diagnostic Port

For dealer maintenance

only. Requires special DDM

monitor supplied to Harman

Dealers exclusively.