P43 low draft voltage adjustment – Harman Stove Company P43 User Manual

Page 20

Advertising
background image

0

P43 Pellet Stove

These units are pre-tested at the factory with exactly

10 Volts A.C., 60 Hz. They are checked and adjusted

for firebox tightness, gasket leakage, motor operation

and igniter operation. The P43 is then factory set at a

mid-point adjustment and in most cases will not need any

adjustments.

nOte: the factory low draft setting may

not be correct for the unit's permanent installation

conditions.

The control board on the P43 is equipped with a low

draft adjustment port. Located on the control face just

to the right of the igniter light. This voltage adjustment

is provided to allow the unit to be adjusted for the

household voltage where the unit is going to be in

permanent operation.

nOte: the line voltage varies

from area to area and often home to home.

The low draft voltage should be adjusted to achieve

the most efficient burn on low burn or "maintenance".

This voltage adjustment allows the installer to change

the low voltage set point approximately 10 volts. This

adjustment should be done by the installer during set

up because a draft meter reading is

required to insure

proper set up.

If the unit is not adjusted properly, it does not cause

a safety concern. If the unit is adjusted too high, only

effiency is lost. If the unit is adjusted too low, the low

draft pressure switch will not allow the feed motor or the

igniter to operate.

C o m b u s t i o n

Motor Speed

Control

Low draft only

set point.

The small straight

screwdriver slot is

plastic; therefore,

the unit can be

adjusted while in

operation.

Fig.

Fig. 3

A simple draft test should be performed after

completing the flue pipe installation. To record the results

for future reference:

1. Plug unit into a 10VAC, 60 HZ outlet.

. Close the hopper lid, front view door, and the ash pan.

Neither pellets or a fire are required for this test.

3. With the mode selector in the "OFF" position, turn

the feed adjuster to "TEST".

4. Record the high draft_____in W.C. (Normal is -.50

to -.60) The control will be on the High Draft for a total

of  minutes.

5. After  minutes, the combustion motor will go down to

low draft and the distribution blower will go on high. Allow

approximately 15 seconds to pass for the combustion

motor to slow before checking the low draft.

6. If the low draft is between -.35 and -.45, record the

reading _____ in W.C. If the reading is higher, slowly

turn the set screw counter-clockwise until the draft

lowers. If the reading is lower, very slowly turn the set

screw clockwise until the draft increases.

nOte: the test mode alternates from high to low

draft every 60 seconds. if more time is needed

for draft adjustment, wait until the next low draft

cycle.

nOte: in some cases, the draft may not go as low

as -.35 to -.45 even with the set screw completely

counter-clockwise. ideally, you should just set it as

low as possible.

low draft voltage adjustment

Draft Meter bolt

hole location

On a P43 the

draft test hole is under

the left rear corner of

the firebox.

P43 low draft voltage adjustment

Advertising