Henny Penny OFG-391 User Manual

Page 13

Advertising
background image

Model OFG- 391

Problem

Cause

Correction

HEATING OF SHORTENING SECTION

• Gas valve knob turned to the OFF

• Make sure the gas valve knob is

position

turned to the ON position.

• Blown fuse or tripped

• Reset breaker or replace fuse

circuit breaker at supply

box or control panel

• Blown fuse in PC board

• Replace glass fuse in board

Faulty POWER/PUMP switch

Check COOK/PUMP switch
per COOK/PUMP Switch Section

Faulty cord and plug

Check cord and plug and
power at wall receptacle

Faulty drain switch

Check drain switch per
Drain Switch Section

Faulty PC board

Remove and replace control
panel

Faulty high limit control switch

Check high limit control
switch per High Temperature Limit
Section

Drain valve open

Close drain valve

Possible faulty gas control

With power removed from

valve

fryer, check across electrical
leads of gas valve
with multimeter, and gas
valve on ON position

Possible faulty temperature probe

Replace temperature probe

Bad spark ignitor

Replace spark ignitor

Low air pressure

Clean or replace blower

Replace air pressure switch

Faulty ignitor module

Replace ignitor module

• Spark ignitor or flame sensor out of

• The spark ignitor needs to be 1/8 in.

adjustment

from the pilot hood, and the
flame sensor, 1/4 in

Shortening will not heat

305

1-7

Advertising