2-1. INTRODUCTION

This section provides checkout and replacement procedures, for
various parts of the fryer. Before replacing any parts, refer to the
Troubleshooting section to aid you in finding the cause of the
malfunction.

2-2. MAINTENANCE HINTS

1. A multimeter will help you to check the electric components.

2. When the manual refers to the circuit being closed, the

multimeter should read zero unless otherwise noted.

3. When the manual refers to the circuit being open, the

multimeter should read infinity.

Do not move the fryer with hot shortening in the frypot or
filter pan. Severe burns can result from splashing hot
shortening.

4. Remove weights from the frame to easily access rear of fryer.

2-3. PREVENTIVE

To ensure a long life of the fryers and their components, regular

MAINTENANCE

maintenance should be performed. Refer to the chart below.

Frequency

Action

Twice Daily

Filter Shortening (See Operator’s Manual)

Monthly

Check Dilution Box, Clean as needed
(See Cleaning the Dilution Box Section)

Annually

Clean Blower Wheel (See Cleaning the
Blower Wheel Section)

Annually

Lubricate Lid Rollers in back of fryer.
(See Lubricating Lid Rollers Section)