2-4. HIGH TEMPERATURE
LIMIT CONTROL

(Continued)

Replacement

To avoid electrical shock or property damage, move the
POWER switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

1. If the tube is broken or cracked, the control will open,

shutting off electrical power. The control cannot be reset.

2. Drain shortening from the frypot and discard. A substance

in the tube could contaminate the shortening.

3. Remove control panel.

4. Loosen small inside screw nut on capillary tube.

5. Remove capillary bulb from bulb holder inside the frypot.

6. Straighten the capillary tube.

7. Remove larger outside nut that threads into pot wall, and remove

defective control from control panel area.

8. Insert new control and replace screws.

9. Uncoil capillary line, starting at capillary tube, and insert

through frypot wall.

To avoid electrical shock or other injury, run the capillary
line under and away from all electrical power wires and
terminals. The tube must never be in such a position where
it could accidentally touch the electrical power terminals.

10. Carefully bend the capillary tube as shown in photo and place

into bulb brackets.