2-19. IGNITOR ASSEMBLY

The 391 has electronic spark ignition, that lights a standing pilot.

Replacement

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

TO AVOID INJURY, PROPERTY DAMAGE, OR
EXPLOSION, BEFORE REPLACING GAS CONTROL
VALVE DO THE FOLLOWING:
• MOVE THE POWER SWITCH TO THE

OFF POSITION.

• DISCONNECT THE MAIN CIRCUIT BREAKER AT

THE WALL, OR UNPLUG THE POWER CORD.

• TURN OFF THE MAIN GAS SUPPLY TO THE

FRYER AND DISCONNECT AND CAP THE SUPPLY
LINE TO FRYER, OR POSSIBLE.

2. Remove the control panel as discussed in Complete Control

Panel Section.

3. Disconnect the 1/4” gas line fitting from the pilot assembly.

4. Follow the wire from the spark ignitor to the module, and remove

the wire from the module.

5. Remove the left, or right side panel, depending upon which

ignitor assembly to be removed.

6. Disconnect gas line (for the left ignitor assembly).

7. Remove the 4 screws securing the burner assembly, and pull the

assembly from the unit.

8. Using a Phillips head screwdriver, remove the screw securing

the ignitor assembly to the burner assembly, and pull the ignitor
assembly from the unit.

9. Secure the new assembly with the screw previously removed,

making sure the assembly is turned to provide a 1/8” gap be-
tween the spark ignitor and the hood of the pilot assembly.

2-19