Model OFG- 391

1-4. ERROR CODES

In the event of a control system failure, the digital display will show
an error message which are coded: “E-4”, “E-5”, “E-6”, “E-10”,
“E-15”, “E-20A-D”, “E-41”, “E-46”, “E-47”, “E-48”, “E-70B”,
and “E-92”. A constant tone is heard when an error code is
displayed; and to silence this tone, press any of the product buttons.

DISPLAY

CAUSE

PANEL BOARD CORRECTION

“E-4”

Control board

Turn switch to OFF position, then turn switch back to ON;

overheating

if display still shows “E-4”, the board is getting too hot; check
for signs of overheating behind the control panel; once panel
cools down, the controls should return to normal; if “E-4”
persists, replace the control

“E-5”

Shortening

Turn switch to OFF position, then back to ON; if display

overheating

shows “E-5”, the heating circuits and temperature probe should
be checked; once the unit cools down, the controls should
return to normal; if “E-5” persists, replace the control

“E-6A”

Temperature

Turn switch to OFF position, then turn switch back to ON;

probe open

if display shows “E-6”, have the temperature probe checked

“E-6B”

Temperature

Turn switch to OFF position, then turn switch back to ON;

probe shorted

if display shows “E-6”, have the temperature probe checked

“E-10”

High limit

Reset the high limit by manually pushing up on the red reset
button; if the high limit does not reset, the high limit must be
replaced; call Henny Penny’s Service Department

“E-15”

Drain switch

Close the drain using the drain valve handle; if display still
shows “E-15”, call Henny Penny’s Service Department

“E-20A”

Air pressure switch

Press the timer button to try the ignition process again; and if

failure (stuck closed)

“E-20A” persists, call Henny Penny’s Service Department

“E-20B”

Draft fan or

Press the Timer button to try the ignition process again; and if

air pressure

“E-20B” persists, call Henny Penny’s Service Department

switch failure
(stuck open)

“E-20C”

Ignition module

Press the Timer button to try the ignition process again; and if

failure

“E-20C” persists, call Henny Penny’s Service Department

“E-20D”

Modules working

Press the Timer button to try the ignition process again; and if

but no ignition

“E-20D” persists, call Henny Penny’s Service Department

1-10