Model OFG- 391

2-4. HIGH TEMPERATURE

11. Pull excess capillary line from pot and tighten nut into frypot wall.

LIMIT CONTROL
(Continued)

Be sure capillary bulb of high limit is positioned so it doesn’t
interfere with the carrier or get damaged when cleaning the
frypot.

12. With excess capillary line pulled out, tighten smaller nut.

13. Replace front panel.

14. Refill with shortening.

2-5. COOK/PUMP SWITCH

The COOK/PUMP switch is a three way rocker switch with a
center OFF position. With the switch in the COOK position the
fryer operates. With the switch in the PUMP position the filter pump
operates, but the unit will not heat.

To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

Checkout

1. Remove control panel.

2. Label and remove wires from the switch.

3. OFF position-should be open circuit anywhere on the switch.

4. COOK position. Check from: #5 to #6 closed circuit

#l to #2 closed circuit

5. PUMP position. Check from: #4 to #5 closed circuit

#3 to #2 closed circuit

Check across the jumpers on the wires of the COOK/PUMP
switch. These jumpers have resistors and capacitors which may
be faulty.