Figure 4-3, Rs232 serial port connection, Figure 4-4 – Honeywell ULTRAKEY LITE HJC5000 User Manual

Page 50: Rs232 serial port connection and megapit

Advertising
background image

50

Installing UltraKey Lite with MAXPRO-Net

Figure 4-3

RS232 Serial Port Connection

Figure 4-4

RS232 Serial Port Connection and MegaPIT

MAXPRO Serial Port (RS232)

RJ45 to

DB9 female

#2(RX)

#5(GND)

#3(TX)

DB9(M axpro)

#6(TX)

#5(GND)

#4(RX)

RJ45 (Ultrakey Lite)

RJ45 to DB9 female

RJ45 to

DB9 female

RJ45 define:
1--RS485_2+/RS422_2_TX+/
RS422_1_RX+
2--RS485_2-/RS422_2_TX-/
RS422_1_RX-
3—NC
4--RS232RX
5--RS232GND
6--RS232TX
7--RS485_1-/RS422_1_TX-
8--RS485_1+/RS422_1_TX+
*RS485_2/RS422_2_TX and
RS232 use same UART_AC

Controller 1

Controller 16

4

4

4

RJ45

Network

Cable

1

RJ45

Network

Cable

1

PSU

3

PSU

3

Controller 1

Controller 8

RS232

MEGAPIT - 1

Controller 249

RS232

Controller 256

MEGAPIT - 32

MEGAPIT
1--RS422_TX+
2--RS422_TX-
3--NC
4--RS232TX
5--RS232GND
6--RS232RX
7--RS422_RX-
8--RS422_RX+

RJ45 define:
1--RS485_2+/RS422_2_TX+/
RS422_1_RX+
2--RS485_2-/RS422_2_TX-/
RS422_1_RX-
3—NC
4--RS232RX
5--RS232GND
6--RS232TX
7--RS485_1-/RS422_1_TX-
8--RS485_1+/RS422_1_TX+
*RS485_2/RS422_2_TX and
RS232 use same UART_AC

MAXPRO Serial Port (RS232) and MegaPIT

RJ45

Network

Cable

1

PSU

3

PSU

3