E. chimney requirements – Hearth and Home Technologies CASTLEWOOD 42 User Manual

Page 11

Advertising
background image

Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev D • 11/11

11

E. Chimney Requirements

When planning your fireplace location, the chimney construc-

tion and necessary clearances must be considered. The fire-

place system and chimney components have been tested to

provide flexibility in construction. The following figures are

the minimum distances from the base of the fireplace.
Minimum overall straight height is 10 ft If the fireplace is

freestanding and a minimum of 10 ft from a combustible

structure.

See Figure 3.2.

• Chimney must extend 2 ft (.6 m) above any portion of

the roof within 10 ft (3048 mm) of the chimney. Refer to

Figure 6.2.

ft

m

Minimum height with offset/return

16

4.88

Maximum height

90

27.43

• Maximum chimney length between an offset

and return

20

6.1

Maximum distance between chimney

stabilizers

35

10.67

Double offset/return minimum height

24

7.32

Maximum unsupported chimney length

between the offset and return

6

1.83

• Maximum unsupported chimney height above

the fireplace

35

10.67

• Minimum overall straight height if fireplace is

freestanding

10

3.048

* Transition section standard with unit and 1 foot section

required in addtion as minimum

or SLA10 (for Canada)

Figure 3.5 Framing the Fireplace

CAK8A required for Canada installation

91/2 ft