Installation of molded brick panel, A. install hearth molded brick panel, B. install back molded brick panel – Hearth and Home Technologies CASTLEWOOD 42 User Manual

Page 19: C. install side molded brick panel

Advertising
background image

Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev D • 11/11

19

7

Installation of Molded Brick Panel

A. Install Hearth Molded Brick Panel

1. Put a level on fireplace to verify it is level side to side

and front to back.

2. While the hearth is removed from the fireplace , measure

all 4 corrners to determine the variance from corner to

corner. See Figure 7.1.

3. Shim the low corners of the hearth refractory by installing

the metal pieces provided on the fireplace bottom. See

Figure 7.2.

4. Put a level on the top flange of the refractory and shim as

necessary from side to side or front to back. See Figure

7.3.

Note: The top flange of the hearth should be level to allow

the sides and back to be installed with minimal gaps. The

hearth slopes towards the front of the unit approximately

1/4”.

B. Install Back Molded Brick Panel

Refer to Figure 7.4.

Set the grate retainer in place, in the notch in the

hearth.

Install the back panel. Center from side to side.

Install rear refractory retainer.

Figure 7.1.

Figure 7.2.

Figure 7.3.

C. Install Side Molded Brick Panel

• Remove screen rods.
• Remove smoke shield
• Install side panel by lifting up, setting on top flange of

hearth and slide towards back of unit until it meets up

with back panel.

• Install refractory retainer
• Install second side panel following the steps above.

Replace the smoke shield.

• Install refractory retainer.

Side Refractory Retainer

Back Refractory Retainer

Back Molded Brick Panel

Grate Retainer

Hearth Retainer

Side Refractory Retainer

Right Side Molded Brick Panel

Left Side Molded Brick Panel

Gas tube locator dimple

Figure 7.4

Advertising