Caution, Chimney assembly, Table 5.1 – Hearth and Home Technologies CASTLEWOOD 42 User Manual

Page 14: A. chimney requirements

Advertising
background image

Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev D • 11/11

14

Vertical distances are measured from the base of the fire-

place.
Minimum overall straight height is 10 ft. if the fireplace is

freestanding and a minimum of 10 ft from a combustible

structure.

• Chimney must extend 2 ft (.6 m) above any portion of the

roof within 10 ft (3 m) of the chimney. To determine the

chimney components needed to complete your particular

installation, follow the steps below:

• Determine the total vertical height of the fireplace

installation. This dimension is measured from the base of

the fireplace assembly to the point where the smoke exits

the termination cap.

• Subtract the effective height of the fireplace assembly from

the overall height of the fireplace installation (measured

from the base of the fireplace to the bottom of the

termination cap).

• Refer to Table 5.1 to determine what components must

be selected to complete the fireplace installation.

• Determine the number of ceiling firestops, stabilizers,

roof flashing, etc. required to complete the fireplace

installation.

Table 5.1

• Do NOT connect this fireplace to a chimney flue

servicing another appliance.

• Do NOT connect to any air distribution duct or

system.

CAUTION

Fire Risk

Must maintain 2 in. (51 mm) air

clearance to insulation and other

combustible materials.

Warning: DO NOT PACK REQUIRED AIR

SPACES WITH INSULATION OR

OTHER MATERIALS.

WARNING

Note: A maximum of two pairs of offsets and returns may

be used.

5

Chimney Assembly

ft

m

Minimum height with offset/return

16

4.88

Maximum height

90

27.43

• Maximum chimney length between an offset

and return

20

6.1

Maximum distance between chimney

stabilizers

35

10.67

Double offset/return minimum height

24

7.32

Maximum unsupported chimney length

between the offset and return

6

1.83

• Maximum unsupported chimney height above

the fireplace

35

10.67

• Minimum overall straight height if fireplace is

freestanding

10

3.048

HEIGHT OF CHIMNEY COMPONENTS

in.

mm

US

Canada ONLY

Chimney Stabilizer

SL11

SL4

4-3/4

121

Ceiling Firestops

FS538

FS538

0

0

FS540

FS540

0

0

Offsets/Returns

SL1130

SL430

14-1/2

368

Chimney Sections*

SL1106

SL406

4-3/4

121

SL1112

SL412

10-3/4

273

SL1118

SL418

16-3/4

425

SL1136

SL436

34-3/4

883

SL1148

SL448

46-3/4

1187

n/a

SLA10

16-3/4

425

n/a

CAK8A

0

0

* Dimensions reflect effective height.

A. Chimney Requirements

* Transition section standard with unit and 1 foot section re-

quired in addtion as minimum

.

Advertising