T8611g chronotherm, Iv deluxe programmable heat pump thermostats – Honeywell Chronotherm IV T8611G User Manual

Page 2

Advertising
background image

69-0936—1

2

T8611G CHRONOTHERM

®

IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

W2

L1
(HOT)

L2

M11311

FAN
RELAY

Y1

G

E

THERMOSTAT

C

HEAT
RELAY
1

R

W1

COMPRESSOR
CONTACTOR

EM. HT.
RELAY

TRANSFORMER

HEAT
RELAY
2

OT

OT

OUTDOOR
SENSOR

COOLING OR
HEATING
CHANGEOVER
VALVE

O/B

X2 L

X1

EQUIPMENT

MONITOR 2

EQUIPMENT

MONITOR 1

1

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

EM. HT. RELAY DOES NOT CYCLE. TO TURN OFF THE EM. HT.,
SET SYSTEM SELECTION TO HEAT.

2

1

2

WIRES
THROUGH WALL

WALL

MOUNTING
HOLES

M15044

MOUNTING
SCREWS

WALL
ANCHORS
(2)

Fig. 1. Typical location of thermostat.

Fig. 3. Typical hookup of T8611G

in a heat pump system.

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M10106

Fig. 2. Mounting the wallplate.

IMPORTANT

Use 18 gauge, color-coded thermostat cable for
proper wiring.

2. Securely tighten each terminal screw.
3. Push excess wire back into the hole.
4. Plug the hole with nonflammable insulation to

prevent drafts from affecting the thermostat.

Advertising