Table 3. Thermostat Installer Setup Options

(Continued).

Installer

Setup

Number

(Press

Time

key to

Factory-Setting

Other Choices

(Press

or

key to change)

Actual

Select

change)

Display

Description

Display

Description

Setting

Extended fan
operation in
cooling

20

0

No extended fan
operation after the
call for cool ends

1

Fan operation is extended
90 seconds after the call for
cool ends.

Not used

21 thru 23

Outdoor
temperature
display
(models with
OT terminals)

24

0

No outdoor
temperature is
displayed

1

Outdoor temperature is
displayed. Needs a C7089B1000
Outdoor Sensor to operate.

Not used

25 thru 28

O/B terminal
energized in
heating or
cooling

29

0

O/B terminal is
energized for
reversing valve in
cooling

1

O/B terminal is energized for
reversing valve in heating

Deadband

30

3

Heating and cooling
setpoints can be set
no closer than 3°F
(1.5°C)

4 thru

10

Heating and cooling setpoints
can be set no closer than the
chosen value:

4—4°F (2°C)
5—5°F (2.5°C)
6—6°F (3°C)
7—7°F (3.5°C)
8—8°F (4°C)
9—9°F (4.5°C)
10—10°F (5°C)

Not used

31 and 32

Minimum off
time for the
compressor

33

5

5 minute minimum
off time for the
compressor

0 thru

4

Minimum number of minutes (0
thru 5) the compressor will be off
between calls for the compressor

Temperature
range stops in
heating

34

90

Highest setpoint
heating can be set to

40 to

89

Temperature range (1°F
increments) heating setpoint
can be set to

Temperature
range stops in
cooling

35

45

Lowest setpoint
cooling can be set to

46 to

99

Temperature range (1°F
increments) cooling setpoint
can be set to

Not used

36

Temperature
display
adjustment

37

0

No difference in
displayed temperature
and actual room
temperature

-3 thru

3

1—Display adjusts to 1°F higher
than actual room temperature
2—Display adjusts to 2°F higher
than actual room temperature
3—Display adjusts to 3°F higher
than actual room temperature
-1—Display adjusts to 1°F lower
than actual room temperature
-2—Display adjusts to 2°F lower
than actual room temperature
-3—Display adjusts to 3°F lower
than actual room temperature

Advertising