Caution, Installer system-test, Setting current day and time – Honeywell Chronotherm IV T8611G User Manual

Page 7: T8611g chronotherm, Iv deluxe programmable heat pump thermostats, Press run program

Advertising
background image

69-0936—1

7

T8611G CHRONOTHERM

®

IV DELUXE PROGRAMMABLE HEAT PUMP THERMOSTATS

Aux Ht

Heat

Auto

System

Fan

Off

Auto

Wake

Mon

Wait

In

Room

Outdoor

%Humid

Auto

Sav

AM

PM

Hold for

Cool

Repl Batt

On

Recovery

DST

Cool

TueWedThuFriSatSun

LeaveReturnSleep

M10345

Set Program

Set Day/Time

Start Time

Temporary Setting Enrg

Em Heat

Em Ht

3. Press Time

or Time

until the current time is

displayed.

NOTE:

Tapping the Set Current Day/Time will
change the time in one hour increments.

M10312

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Mon

PM

Set Day/Time

2. Press Day until the current day is displayed.

NOTE:

Sun=Sunday, Mon=Monday,
Tue=Tuesday, Wed=Wednesday,
Thu=Thursday, Fri=Friday, Sat=Saturday.

M10313

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Day

Heat/Cool

Settings

Daylight

Time

Copy

PM

Tue

Set Day/Time

M10314

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Time

Heat/Cool

Settings

Daylight

Time

Copy

AM

Tue

Set Day/Time

NOTE:

If the current time is Daylight Savings
Time, press Daylight Time until DST is
displayed.

M10316

Time

Set Program

System

Fan

Run

Program

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Copy

Auto

System

Fan

Wake

Room

AM

DST

Tue

Heat

M10315

Time

Set Program

System

Fan

Run

Program

Hold Temp

Set Current

Day/Time

Wake

Leave

Return

Sleep

Day

Heat/Cool

Settings

Daylight

Time

Daylight

Time

Copy

AM

DST

Tue

Set Day/Time

4. Press Run Program.

INSTALLER SYSTEM-TEST

Use the Installer System-Test to check the thermostat
operation. Refer to Table 4 for a list of the available
system-tests.

To start the system-test:

CAUTION

The minimum off time for compressors is
bypassed during the Installer System-Test.
Equipment damage can occur if the compressor
is cycled too quickly.

Press and hold the increase

and decrease

keys at

the same time until 10 appears. All segments of the
display will be displayed before the 10 appears. See
Fig. 11 and 12.

Table 4. Tests Available In The Installer System-Test.

Fig. 11. Display of all the segments of the LCD.

Fig. 12. Display of test number.

M10257A

TEST NUMBER

IMPORTANT

Review the settings to confirm that they match
the system. Press Run Program to exit the
Installer Setup. The thermostat has saved the
Installer Setup changes and initiated a reset in
order to operate using the new settings. Be sure
to set the current day and time immediately.

Setting Current Day and Time

1. Press Set Current Day/Time.

NOTE:

On initial power up or after an extended
power loss, 1:00 pm flashes on the
display until a key is pressed.

Test

Number

System-Test Description

10-19

Heating equipment can be turned on
and off

20-29

Emergency heat equipment can be turned
on and off

30-39

Cooling equipment can be turned on
and off

40-49

Fan equipment can be turned on and off.

60 0 to
60 19

Keyboard keys test

70-79

Thermostat information including date
code and software versions are displayed

Advertising