PROBLEM OR CONCERN POSSIBLE CAUSE

SOLUTION

Gun/Hose - Leaking water

Gun/Hose will need to be replaced. Replacement parts
are not available for the Gun/Hose. Email us at:
[email protected]
for assistance or order online at:
www.huskypowerwasher.com.

Leaking Oil from Pump

A small amount of leakage is
normal

If leakage occurs please contact use directly at
[email protected].

Leaking water from bottom
of unit

Machine Inlet connection is de-
fective

Check the Machine Inlet at the front of the unit
to ensure that water is not leaking from it. If the
connection is leaking it will have to be replaced.
Contact us at:
[email protected]
or order a replacement directly online at:
www.huskypowerwasher.com

.

Pump housing is leaking water

Email us at:
[email protected]
for assistance.

Low pressure

Faucet not fully open or unit is not
receiving a full volume of water

Open the faucet all the way.

Not building maximum Pressure Screen Filter is clogged

Clean the Screen filter as instructed in the section 5.4.

Irregular Pressure

Gun or Hose failure

Replace Gun and/or Hose. Contact us at:
[email protected]
or order online at:
www.huskypowerwasher.com

.

Kink in the Garden Hose or Hose
is wrapped on a storage wheel

Unwrap the Garden Hose and lay it out flat to
ensure that there are no kinks in the Hose.

Water leaking from either Hose
or Unit

Stop water from leaking before using the unit or
contact us if you need assistance.

Garden Hose length is too long Shorten the length of the Garden Hose. We

recommend a maximum length of 25 to 50
feet for City water supply and 30 feet for Well
water supply.

Clogged Nozzle

Clean the Nozzle as instructed in section 5.2.

Air in Pump

Let Pressure washer run with Gun trigger depressed
and Wand removed until a steady stream of water
is released.

No Wand attached to the front
of the Gun

Attach either the Click-N-Clean

TM

or Turbo

Wand to the gun. (High Pressure in created with
the Wand and not the Gun).

No water coming out of Wand Clogged Nozzle

Clean Nozzle as instructed in section 5.2.

Quick Connect is attached
incorrectly

See section 3.2. To Attach Quick Connect properly,
keep the outer collar of the Quick Connect held back
while sliding the Quick Connect all the way forward
against the Inlet Nipple and then release the collar to
lock it into place. (The collar is spring loaded so if it is
released too soon it will not lock into place).

Sceen Filter is clogged

Clean the Sceen filter as instructed in section 5.4.

Kink in the Garden Hose or Hose

is wrapped on a storage wheel

Unwrap the Garden Hose and lay it out flat to

ensure that there are no kinks in the Hose.