PROBLEM OR CONCERN

POSSIBLE CAUSE

SOLUTION

Unit will not stop when trigger is
released (contd)

Wand is malfunctioning

Test both wands to ensure that one is not

malfunctioning.

Gun is not operating properly Remove Wand from the Gun and squeeze trigger to

ensure that the water is coming out of the front of the

Gun at a rate equal to the Garden Hose.

Wand - Attaching

To attach the Wand apply some moderate downward

pressure force on the Wand (In the direction of the

trigger) while simultaneously twisting the wand a 1/4

of a turn counterclockwise. (It may help if you set the

gun vertically on a flat surface with the wand pointing

upwards). The two tabs on the end of the Wand must

slide all the way in before the Wand will twist and

lock. If this does not work remove the o-ring from the

end of the wand and attach it without the o-ring. If the

wand attaches, you will need to replace the o-ring.

Contact us at:

[email protected]

or order a replacement directly online at:

www.huskypowerwasher.com

.

Wand - Removing

Release the back pressure in the Gun/Hose.

Remove the Garden Hose from the unit and

squeeze the trigger of the Gun. Apply some

moderate downward pressure force on the

Wand (In the direction of the trigger) while

simultaneously twisting the wand a 1/4 of

a turn clockwise. (It may help if you set the

gun vertically on a flat surface with the Wand

pointing upwards). For additional assistance

you can email us at:

[email protected].

The green “Ready” light is not

illuminated.

NOTE: The green “Ready” light

should illuminate when the machine

is plugged in and the ON button is

depressed.

No power

Check that the circuit is dedicated and rated

at 15 amps or greater.

The yellow “Medium” light will

not illuminate.

NOTE: The yellow “Medium” light

will only illuminate when using the

turbo wand or the Click-N-Clean

TM

wand set to the “Medium Fan Spray”

or “Detergent Spray” position and

the gun trigger is depressed motor is

running and water is spraying from

the nozzle.

The Click-N-Clean

TM

is not set

to the proper position.

Make sure that the Click-N-Clean

TM

wand is set

to the “Medium Fan Spray” or “Detergent Spray”

position.

Use of improper extension

cord.

Use proper extension cord as recommended in

Owner’s Manual.

Clogged nozzle

Clean nozzle as instructed in Owner’s Manual

section 5.2.

The blue “High” light will not

illuminate.

NOTE: The blue “High” light will

only illuminate when the Click-N-

Clean

TM

wand is set to the “High

Pressure Fan Spray” position

and the gun trigger is depressed,

motor is running and water is

spraying from the nozzle.

Faucet not fully open or unit is

not receiving a full volume of

water.

Ensure that the faucet is fully open.

Check garden hose connection and ensure that

the garden hose meets criteria as described in the

Owner’s Manual.

Screen filter clogged.

Clean the screen filter as instructed in Owner’s

Manual section 5.4.