Figure 9 – Heat & Glo Fireplace ST-38HV-AU User Manual

Page 12

Advertising
background image

12

Figure 9

V

11

V

H

11

H

H

V

H

11

H

22

FLUEING WITH THREE (3) 90° ELBOWS

V

H

H + H

1

1´ MIN. (305 mm)

2´ MAX. (610 mm)

2´ MAX. (610 mm)

2´ MIN. (610 mm)

2´ MAX. (610 mm)

4´ MAX. (1.22 m)

3´ MIN. (914 mm)

2´ MAX. (610 mm)

6´ MAX. (1.86 m)

4´ MIN. (1.22 m)

2´ MAX. (610 mm)

8´ MAX. (2.4 m)

5´ MIN. (1.52 m)

2´ MAX. (610 mm)

10´ MAX. (3.04 m)

6´ MAX. (1.86 m)

2´ MAX. (610 mm)

12´ MAX. (3.65 m)

7´ MAX. (2.13 m)

2´ MAX. (610 mm)

14´ MAX. (4.26 m)

14´ MAX. (4.26 m)

V + H + H

1

= 37’ MAX. (11.3 m)

HEAT SHIELD

NOTE: When the 45

0

elbow is attached horizon-

tally, the supplied heat shield must be installed.