5

Clearance Requirements

The top, back, and sides of the heater are
defined by stand-offs.

The minimum clearance to a perpendicular
wall extending past the face of the heater is
one inch (25mm). The metal ends of the heater
may NOT be recessed into combustible
construction.

Figure 2. Heater Dimensions, Locations,
and Space Requirements

1.1 Locating the Heater

The diagram (See figure 2) shows space and
clearance requirements for locating a heater
within a room.

Minimum Clearances from the Heater to

Combustible Materials

Glass

Exhaust Side Opposite Side

Top of

Front

Floor

of Heater

of Heater

Heater

Ceiling

36 inches

0

2-1/2 inch

0

5-1/2 inches

36 inches

(914 mm)

(64 mm)

(127 mm)

(914 mm)

36” (914mm)

36” (914mm)

1” (25mm)

NOTE: The clearance to the ceiling is measured from the top of the unit excluding
standoffs.