C rated wire, Fan wiring diagram – Heat & Glo Fireplace ST-38HV-AU User Manual

Page 18

Advertising
background image

18

Figure 21

NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED,
IT MUST BE REPLACED WITH TYPE
105

C RATED WIRE.

JUNCTION BOX

JUNCTION BOX

FAN

BLUE

BROWN

YELLOW/GREEN

BLUE

BRN

YW/GR

BLK

BLK

TEMP. SENSOR

SWITCH

TEMP. SENSOR

SWITCH

BLK

BLK

SPEED CONTROL

SPEED CONTROL

FAN WIRING DIAGRAM

FAN WIRING DIAGRAM

BLK

BLK

YELLOW/GRN

YELLOW/GRN

BLUE

BRN

BRN

BLUE

GRD

BLUE

JUNCTION BOX DETAIL

JUNCTION BOX DETAIL

FAN

FAN

TEMPERATURE

SENSOR SWITCH

TEMPERATURE

SENSOR SWITCH

FAN SPEED

CONTROL

FAN SPEED

CONTROL

JUNCTION BOX

JUNCTION BOX

NOTE:

IF THE SUPPLY CORD IS DAMAGED, IT

MUST BE REPLACED BY THE MANUFACTURER,
AN AUTHORIZED SERVICE AGENT, OR A SIMI-
LARLY QUALIFIED PERSON IN ORDER TO AVOID
A HAZARD.

Advertising