19

FIGURE 24

FIGURE 23

FIGURE 22

1.5.1 INSTALLING THE ELECTRICAL

SERVICE TO THE JUNCTION BOX

WARNING:

TURN ELECTRICAL POWER OFF AT

THE CIRCUIT BREAKER BEFORE BEGINNING IN-
STALLATION.

1. Remove the electrical cover plate from the lower side

of the heater. Remove the knockout from the plate
and attach the Romex clamp (screws to the out-
side.)

2. Feed the electrical services wires through the Romex

clamp and secure the wire to the clamp.

3. Using the wire connector provided inside the junc-

tion box, attach the neutral service wire to the blue
wire, the hot service wire to the black wire, and the
service ground wire to the ground screw stud of the
junction box. See Figure 22 for wire connection de-
tail and Figure 21 for a complete wiring diagram.

4. Re-attach the cover plate to the outside of the heater.

WARNING:

DO NOT CONNECT 220 VAC

TO THE GAS CONTROL VALVE OR CON-
TROL WIRING SYSTEM OF THIS MODEL.

1.6 MANTEL CLEARANCES

Clearance to a mantelpiece is 6-inches (152mm). See
Figure 23.

IF JOINTS BETWEEN THE FINISHED WALLS AND
THE FIREPLACE SURROUND (TOP AND SIDES)
ARE SEALED, A 150°

C. MINIMUM SEALANT

MATERIAL MUST BE USED. THESE JOINTS ARE
NOT REQUIRED TO BE SEALED. ONLY NON-
COMBUSTIBLE MATERIAL (USING 150° C.
MINIMUM ADHESIVE, IF NEEDED) CAN BE
APPLIED AS FACING TO THE FIREPLACE
SURROUND. SEE FIGURE 24.

1.7 LOG INSTALLATION

Carefully remove the log packages from the heater
and the tags from their packages. Handle logs gently.
Place the logs in the heater by following the steps
shown in Figure 25. Replace the glass door and dress
guard previously removed prior to lighting the unit. Be
certain the gas logs are properly positioned.

NOTE: ALL DIMENSIONS ARE
SHOWN IN MILLIMETERS

.

TOP FRONT EDGE

OF FIREPLACE

152

178

229

254

279

152

178

203

229

254

279

203

HIGH TEMP

(300 F. 150 C. MIN.)

SEAL JOINT

o

o

STUD

TOP STANDOFF

FINISHED

WALL

2 X 4

HEADER

HIGH TEMP

(300 F. 150 C. MIN.)

SEAL JOINT

o