Step 5. Label Old Thermostat Wires

1. As you disconnect each wire, use the enclosed wire

labels to wrap a wire label around each wire that

matches the letter designation. Do not allow the

wires to fall into the wall opening after the wires are

disconnected.

2. Remove any remaining part of the old thermostat

from the wall.

When connecting the wires to the new

thermostat, refer to the wire labels. Do not

connect wires to your new thermostat based on

the color of the wire.

Y

G

R

C

R

OLD THERMOSTAT

WIRE HOLE

M22039

WIRE

SCREW
TERMINAL

LETTER
DESIGNATION

WIRE LABEL

W

W

G

Y

R

RC

69-1730.fm Page 10 Tuesday, July 13, 2004 12:45 PM