Step 11. Configure Installer Setup (Cont)

8. Press the Up or Down arrows to select your setting

for Installer Setup Number 0170.

9. After you select your setting, press the Next button

to go to the next Installer Setup Number.

M22308

0170

System

Type

Selection

1 - Heating and Cooling (Conventional) -- Gas, oil or
electric heating with central air conditioning.
2 - Single-stage Heat Pump with no back-up or
auxiliary heat
-- the compressor runs in both
heating and cooling.
3 - Heat Only with no fan (Conventional) -- Gas, oil
or electric heating without central air conditioning.
No wire on the G terminal on new thermostat.
4 - Heat Only with fan (Conventional) -- Gas, oil or
electric heating without central air conditioning.
Typically wires are R, W and G on new thermostat.
5 - Hot Water Heat Only (Conventional) -- Gas or Oil
hot water heat with three wires connected to new
thermostat or for normally closed hot water values
with wires connected to R and Y on new thermostat.
6 - Cool Only (Conventional) -- Central air
conditioning only.
7 - Multistage Heat Pumps -- heat pump with auxiliary
or back-up heat.
8 - Multistage Conventional Heating and Cooling --
2 stages of Heat (wires on W and W2) and 2 stages
of Cool (wires on Y and Y2).
9 - Multistage Conventional Heating and Cooling --
2 stages of heat (wires on W and W2) and 1 stage
of Cool (wire on Y).
10 - Multistage Conventional Heating and Cooling --
1 stage of heat (wire on W) and 2 stages of Cool
(wires on Y and Y2).

UP

ARROW

DOWN

ARROW

SETTING

ADVANCE
TO NEXT
INSTALLER SETUP

PRESS TO EXIT

INSTALLER SETUP

GOES BACK TO
LAST INSTALLER
SETUP

Clock

More

Done

Next

Go Back

INSTALLER
SETUP NUMBER

%

Set To

Installer

Setup

Number

Installer

Setup
Name

(Select Your Setting)

Settings

69-1730.fm Page 30 Tuesday, July 13, 2004 12:45 PM

Advertising