Honeywell RTH7500D User Manual

Page 60

Advertising
background image

69-1730

60

Cannot set

System setting

to Cool.

Check Installer Setup Number 0170,

Heating and/or Cooling System Type; make

sure the setting matches the installed

heating and/or cooling system.

“Heat On” is

not shown in

the display.

Set the System setting to Heat and set the

temperature setting above the room

temperature. If “Heat On” is shown solidly in

the display, but the heating system does not

turn on, see “Heating system does not turn

on” in the Troubleshooting Tips.

“Cool On” is

not shown in

the display.

Set the System setting to Cool and set the

temperature setting below the room

temperature. If “Cool On” is shown solidly in

the display, but the cooling system does not

turn on, see “Cooling system does not turn

on” in the Troubleshooting Tips.

“Wait” shows in

the display.

Compressor minimum-off timer is active.

Wait up to five minutes for the cooling or

heating system to turn on.

Fan does not

turn on in a call

for heat

(electric fur-

naces only).

Check Installer Setup Number 0180, Fan

Control in Heating, and make sure it is set

to Electric Heat.

Heat pump

puts out cool

air in the heat

mode and

warm air in the

cool mode

(heat pumps

only).

Check Installer Setup Number 0190, Heat

Pump Changeover Valve, and make sure

the setting matches the changeover

required by the installed heat pump.

Troubleshooting Tips (Cont)

If . . .

Then . . .

69-1730.fm Page 60 Tuesday, July 13, 2004 12:45 PM