Discharging combustion products (exhaust), Adapting to different types of gasses – Foster Gas Cooker Hobs 9606801 User Manual

Page 13

Advertising
background image

31

ENGLISH

INSTALLER INSTRUCTIONS

10. Discharging combustion products

(exhaust)

Discharge of combustion products must be ensured through hoods connected to an

efficient natural draught flue, or through a forced exhaust.
An efficient exhaust system requires an accurate design by a specialist that is ap-

proved for this work, following positions and distances contained in regulations.

IMPORTANT: At the end of the intervention the installer must issue a conformity

certificate.

11. Adapting to different types of gasses

Gas

type

Burner

Rated

capacity

(KW)

Rated con-

sumption

(g/h)

Injector

(ø mm)

Min

rated capacity

(KW)

Series No.

Ref.

LPG GAS

G30/G31 28÷30/37 mbar

II

2

Auxiliary

1,00

73

0,50

0,52

3

Semi-quick

1,75

127

0,65

0,52

4

Quick

2,70

196

0,80

0,90

5

Triple crown

3,50

254

0,95

1,80

10

Dual

4,50

328

i 0.46 / and 0.66 i 0.46 / and 0.66

III

6

Auxiliary

1,10

80

0,52

0,52

7

Semi-quick

1,75

127

0,65

0,52

8

Quick

3,00

218

0,85

0,90

9

Triple crown

3,80

276

0,98

1,80

AE

11

Auxiliary

1,00

73

0,50

0,52

12

Semi-quick

1,75

127

0,65

0,52

13

Quick

3,00

218

0,85

0,90

14

Dual gear

5,00

364

i 0.46 / and 0.95 i 0.30 / and 1.40

INSTALLER INSTRUCTIONS