INSTALLER INSTRUCTIONS

IMPORTANT: After adjusting for use with a gas that is different from the initial testing

one, replace the label on appliance housing with the one that corresponds to the new

gas type.

12. Adjustment of the minimum

Instructions for urban and methane gas
1. Light the burner and bring it to the minimum

position.

2. Remove the gas tap knob and turn the adjust-

ment screw [

Fig. 8

] inside or on the side of the

tap rod (depending on the model), until a regular

minimum flame is obtained.

3. Re-assemble the knob and verify burner flame

stability (when quickly rotating the hand from

maximum to minimum position the flame must

not shut off).

4. Repeat the operation on all gas taps.

Fig. 8:

adjustment of the minimum

Instructions for liquid gas (LPG)
Tighten the screw inside, or on the side of the tap (depending on the mode), rod

clockwise completely.

13. Electrical connection of the cooker hob

IMPORTANT: Before completing the following operation, always make sure that the

voltage and sizing of the power supply line correspond to the characteristics indicated

on the place located under the housing of the appliance. This plate must never be