1 cooker hob nozzle replacement – Foster Gas Cooker Hobs 9606801 User Manual

Page 14

Advertising
background image

32

ENGLISH

INSTALLER INSTRUCTIONS

Gas

type

Burner

Rated

capacity

(KW)

Rated con-

sumption

(l/h)

Injector

(ø mm)

Min

rated capacity

(KW)

Series No.

Ref.

METHANE GAS G20 20 mbar

II

2

Auxiliary

1,00

95

0,72

0,52

3

Semi-quick

1,75

167

0,97

0,52

4

Quick

2,70

257

1,08

0,90

5

Triple crown

3,50

333

1,35

1,80

10

Dual

4,50

429

i 0.72 / and 1.02 i 0.46 / and 0.66

III

6

Auxiliary

1,10

105

0,73

0,52

7

Semi-quick

1,75

167

0,98

0,52

8

Quick

3,00

285

1,26

0,90

9

Triple crown

3,80

362

1,35

1,80

AE

11

Auxiliary

1,00

95

0,72

0,52

12

Semi-quick

1,75

167

0,97

0,52

13

Quick

3,00

285

1,32

0,90

14

Dual gear

5,00

476

i 0.75 / and 1.58 i 0.30 / and 1.40

The appliance is tested for methane gas G20 (2H) at a pressure of 20 mbar. When

using with other types of gas it is necessary to replace the burner nozzles, and adjust

the minimum flame on the gas taps. For nozzle replacement, proceed as described in

the following paragraphs.

11.1 Cooker hob nozzle replacement

IMPORTANT: Before completing the following operations, always make sure that the

appliance is disconnected from the power mains.

1. Remove the grids, remove all flame spreading

caps and crowns.

2. Using a 7 mm tube spanner, unscrew the burner

nozzles [

Fig.7

].

3. Proceed with burner nozzle replacement based on

the type of gas to be used (table “Adapting to

different types of gasses

[

Page 31

]).

4. Correctly reposition the burner in its seat.

Fig. 7:

nozzle replacement

Advertising