Frymaster FOOTPRINT 8196345 User Manual

Page 12

Advertising
background image

1-6

Pressure

(m bar)

Gas

Single

Vat

Natural Gas Lacq
(G20) under 20 mbar

7

Natural Gas Gronique *
(G25) under 25 mbar

10

Natural Gas Gronique
(G25) under 20 mbar

10

Butane/Propane
(G30) at 28/30 or 50 mbar

17

Propane
(G31) under 37 or 50 mbar

20

CE Standard

Burner M anifold Gas Pressures

* Belgian G25 = 7,0 m bar

Gas

Pressure

Natural

3" W.C.

0.73 kPa

Propane

8.25" W.C.

2.5 kPa

Non-CE Standard

Burner Manifold Gas Pressures

6. To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust to the

correct pressure.

Non-CE

Valve

CE

Valve

GAS VALVE REGULATOR CAP

7. Place the fryer power switch (and the gas valve in non-CE fryers) in the OFF position. Remove

the fitting from the pressure tap hole and reinstall the pressure tap plug.

Advertising