1.13.2 ATO (Automatic Top-Off) Board Pin Positions and Harnesses

Connector

From/To

Harness #

Pin #

Function

Voltage

Wire Color

1

Output DV - Vat #1

Green

2

Output FV - Vat #1

Red

3

Output DV - Vat #2

Green

4

Output FV - Vat #2

Red

5

Output DV - Vat #3

Green

Solenoids

8074718 (FV)

8074717 (DV)

6

Output FV - Vat #3

Ground

Red

Top Off Pump

7

Top Off Pump

Red

JIB Reset Switch

8074719

8

JIB Low Reset

16VDC

Black

9

24VAC DV - Vat #1

White

10

24VAC FV - Vat #1

Black

11

24VAC DV - Vat #2

White

12

24VAC FV - Vat #2

Black

13

24VAC DV - Vat #3

White

Solenoids

8074718 (FV)

8074717 (DV)

14

24VAC FV - Vat #3

24VAC

Black

15

J8

Top Off Pump & JIB

Reset Switch

8074719

16 Ground

16VDC

Red

1 24VAC

Ret

Orange

2 24VAC

24VAC

Blue

3
4

5 12VAC

Ret

Red

6 12VAC

12VAC

Brown

7

J4 (Rear) /

J5 (Front)

Transformer 8074553

8

1

DV - Probe Ground

White

2

DV - Probe

Red

3

FV - Probe Ground

White

J1 - Vat #1
J2 - Vat #2
J3 - Vat #3

ATO RTD

8074655 - Vat #1
8074654 - Vat #2
8074654 - Vat #3

4

FV - Probe

Ohm

Red

1 16VDC

Black

J6 Orange

LED 8074555

2 16VDC

Ret

16VDC

Red

1

2

3 Ground
4 RB7/DATA

J7

5 RB6/CLOCK

1 Ground

Black

8074552

(Network Resistor)

2 CAN

Lo

Red

3 CAN

Hi

White

4

5

J10

Network Resistor

(pins 2 & 3)

or to next ATO Board

(4 & 5 vat units)

8074546

to next ATO board.

6

1 Ground

Black

2 CAN

Lo

Red

3 CAN

Hi

White

4

5

J9 CM7

J6/J7 8074646

6

Advertising