Problem probable causes corrective action – Frymaster FOOTPRINT 8196345 User Manual

Page 40

Advertising
background image

1-34

Problem

Probable Causes

Corrective Action

CM7 display shows

PROBE

FAILURE.

Problem with the temperature
measuring circuitry including the
probe.

This indicates a problem within
the temperature measuring
circuitry. Check resistance of
probe, if faulty replace probe.

CM7 display shows

PROBE

FAILURE with

alarm sounding.

Damaged computer wiring harness or
connector.

Swap the computer wiring harness
with one known to be good. If
problem is corrected replace the
harness.

CM7 display shows

IGNITION

FAILURE.

Open drain valve, failed computer,
failed interface board, open high-
limit thermostat.

Is displayed if the fryer loses its
ability to heat oil. It is also
displayed when the oil
temperature is above 450°F
(232°C) and the high-limit
thermostat has opened, halting the
heating of the oil.

Computer will not

go into program

mode or some

buttons do not

actuate.

Failed computer.

Replace computer

CM7 display shows

low temp,

heating indicator

cycles on and off

normally but fryer

does not heat.

A. Failed computer.

B. Damaged computer wiring

harness.

A. Replace computer.

B. Replace computer wiring

harness.

CM7 display shows

igNITION

FAILURE with

alarm sounding.

Heating indicator is

on, but fryer is not

heating.

Drain valve not fully closed.

Press the reset switch on the MIB
board. All drain valves should
close. Using the ON/OFF switch,
turn the computer OFF and then
ON again.

CM7 display shows

IGNITION

FAILURE and

alarm sounds, but

fryer operates

normally (false

alarm).

Failed computer.




Replace computer.

CM7 display shows

HI 2 BAD.

Computer in high-limit test mode.

This is displayed only during a
test of the high-limit circuit and
indicates that the high-limit has
failed.