5-4

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

A. Thermal overload switch has tripped

on an overheated motor.

Test: If the pump stopped suddenly
during the filtering process,
especially if after several filtering
cycles, the pump motor has probably
overheated. Place the filter handle in
the OFF position, allow the pump to
cool for at least 45 minutes, and then
press the reset button on the pump
motor. Attempt to activate the pump.

A. If the pump runs normally after

resetting the thermal overload switch,
the pump was overheated.

Always filter with the cooking
oil/shortening at or near frying
temperature.

Allow the pump motor to cool off for
about ten minutes after filtering two
full frypots one after the other.

Check the filter paper between
filterings. Replace the paper if there
is a large accumulation of sediment.

B. Failed filter-handle microswitch.

Test: If this is a multi-pot fryer,
attempt to operate the pump using a
different handle. If the pump starts,
the handle microswitch is either out
of alignment or has failed.

When the handle is placed in the ON
position, the lever on the microswitch
should be firmly pressed against the
switch. If so, the switch has failed. If
not, the switch is loose and/or
misaligned.

B. If the switch is loose, tighten the nuts

and bolts holding it in place, ensuring
that when the handle is placed in the
ON position, the lever on the
microswitch is pressed firmly against
the switch.

If the switch has failed, call FASC.

Pump won’t start.

OR

Pump stops during

filtering.

C. Pump blockage.

Test: Close the drain valve. Place
the filter handle in the OFF position,
allow the pump to cool for at least 45
minutes, and then press the reset
button on the pump motor. Pull the
filter pan from the unit and then
activate the pump. If the pump motor
hums and then stops, the pump is
blocked.

C. Pump blockages are usually caused

by sediment build-up in the pump
due to improperly sized or installed
filter paper and failure to use the
crumb screen. Call FASC to have
blockage cleared.

Ensure that filter paper is of the
proper size and is installed properly,
and that the crumb screen is used.

Advertising