Frymaster Enodis MRE14 SERIES User Manual

Page 11

Advertising
background image

1-3

1.4 Replacing a High-Limit Thermostat

1. Remove the filter pan and lid from the unit. Drain the frypots into an McDonald’s Shortening

Disposal Unit (MSDU) or other appropriate metal container.

DANGER

DO NOT drain more than one full frypot or two split frypots into the MSDU at one time.


2. Disconnect the fryer from the electrical power supply and reposition it to gain access to the rear

of the fryer.

3. Remove the four screws from both the left and right sides of the lower back panel.

4. Locate the high-limit that is being replaced and follow the two-black wires to the 12-pin

connector C-6. Note where the leads are connected prior to removing them from the connector.
Unplug the 12-pin connector C-6 and using a pin-pusher push the pins of the high-limit out of
the connector.

5. Using a wrench, carefully unscrew the high-limit thermostat to be replaced.

6. Apply Loctite

PST 567 or equivalent sealant to the threads of the replacement and screw it

securely into the frypot.

7. Insert the leads into the 12-pin connector C-6 (see illustration below). For full-vat units or the

left half of a dual-vat unit (as viewed from the rear of the fryer) the leads go into positions 1 and
2 of the connector. For the right half of a dual-vat unit (as viewed from the rear of the fryer), the
leads go into positions 7 and 8. In either case, polarity does not matter.

8. Reconnect the 12-pin connecting plug C-6. Use wire ties to secure any loose wires.

9. Reinstall the back panels, reposition the fryer under the exhaust hood, and reconnect it to the

electrical power supply to return the fryer to service.



1.5 Replacing a Temperature Probe


1. Remove the filter pan and lid from the unit. Drain the frypots into a McDonald’s Shortening

Disposal Unit (MSDU) or other appropriate metal container.

DANGER

DO NOT drain more than one full frypot or two split frypots into the MSDU at one time.