22. Position the element tube assembly in the frypot and reinstall the machine screws and nuts

removed in step 14.

23. Reconnect the oil return flexlines to the frypot, and replace aluminum tape, if necessary, to

secure heater strips to the flexlines.

24. Insert the high-limit thermostat leads disconnected in step 13 (see illustration on page 1-3 for pin

positions).

25. Reconnect the drain safety switch wiring to the switch(es) in accordance with the diagram below

then reinstall the switch covers.

26. Reinstall the drain tube assembly.

27. Reinstall the top connecting strips, top cap, tilt housing and back panels.

28. Reinstall controllers in the control panel frame and reconnect the wiring harnesses and ground

wires.


29. Reposition the fryer under the exhaust hood and reconnect it to the electrical power supply.



1.9 Built-in Filtration System Service Procedures


1.9.1 Filtration System Problem Resolution

One of the most common causes of filtration problems is placing the filter paper on the bottom of the
filter pan rather than over the filter screen.

CAUTION

Ensure that filter screen is in place prior to filter paper placement and filter pump

operation. Improper screen placement is the primary cause of filtration system

malfunction.

Whenever the complaint is “the pump is running, but no oil is being filtered,” check the installation
of the filter paper, and ensure that the correct size is being used. While you are checking the filter
paper, verify that the O-rings on the pick-up tube of the filter pan are in good condition. A missing
or worn O-rings allow the pump to take in air and decrease its efficiency.