1-1

BIRE14/MRE14 SERIES ELECTRIC FRYERS

CHAPTER 1: SERVICE PROCEDURES


1.1 General


Before performing any maintenance on your Frymaster fryer, disconnect the fryer from the electrical
power supply.

WARNING

To ensure the safe and efficient operation of the fryer and hood, the electrical plug
for the 120-volt line, which powers the hood, must be fully engaged and locked in its
pin and sleeve socket.

When electrical wires are disconnected, it is recommended that they be marked in such a way as to
facilitate re-assembly.

1.2 Replacing a Computer

1. Disconnect the fryer from the electrical power supply.

2. The controller bezel is held in place by tabs at the top and bottom. Slide the metal bezel up to

disengage the lower tabs. Then slide the bezel down to disengage the upper tabs.

3. Remove the two screws from the upper corners of the control panel. The control panel is hinged

at the bottom and will swing open from the top.

4. Unplug the wiring harness from the connector on the back of the computer and disconnect the

grounding wire from terminal adjacent to the connector. Remove the control panel assembly by
lifting it from the hinged slots in the control panel frame.

5. Remove the controller from the control panel assembly and install the replacement computer.

Reinstall the control panel assembly by reversing steps 1 and 2.


1.3 Replacing Component Box Components

1. Disconnect the fryer from the electrical power supply.

2. The controller bezel is held in place by tabs at the top and bottom. Slide the metal bezel up to

disengage the lower tabs. Then slide the bezel down to disengage the upper tabs.