2 diagnostics, 1 self test at power on – Furuno FELCOM 16 User Manual

Page 152

Advertising
background image

7. MAINTENANCE, TROUBLESHOOTING

7-2

7.2 Diagnostics

The system is equipped with a diagnostic test which check it for proper
operation.

7.2.1

Self test at power on

The terminal unit performs the ROM sum check and RAM read and write test
when turned on. If the test results are normal the equipment goes into standby. If
error is found you cannot transmit. Contact your dealer for advice.

7.2.2

Testing the communication unit through the keyboard,
displaying program version no.

The communication unit must be idle to execute the test.

1. Press the [F7] key to display the Options menu.

Options

1. Login

2. Logout
3. Abort
4. Select NCS
5. Ocean Region
6. LES Information
7. Test

FELCOM functions as
Inmarsat MES

Options

1. Login

2. Logout
3. Abort
4. Select EGC Ch.
5. LES Information
6. Test

FELCOM functions as
EGC receiver

Options menu

2. Press the [7] key ([6] key if the FELCOM 16 functions as an EGC receiver) to

display the Test menu.

Test

1. PV Test

2. PV Test Result
3. Diagnostic Test

Test menu

3. Press the [3] key to choose Diagnostic Test.

1. Login
2. Logout
3. Abort
4. Select NCS
5. Ocean Region
6. Test

Options

1. PV Test
2. PV Test Result
3. Self Test
4. Distress Alarm Button Test

Test

Start

No

Yes

Yes

Diagnostic Test

Start window

4. Yes is selected; press the [Enter] key to start the test. The message “Now

testing” (flashing) appears during the testing.

When the test is completed, the screen shows the test results as shown at
the top of the next page.

Advertising