Frymaster Heated Landing Zone HLZ 22 User Manual

Page 12

Advertising
background image

Frymaster L.L.C., 8700 Line Avenue 71106, P.O. Box 51000, Shreveport, Louisiana 71135-1000

318-865-1711 FAX 318-862-2394

Printed in the United States Service

Hotline

Page

10

1-800-24-FRYER




9.3 Repair Procedures

1. Accessing the interior of the HLZ (Set up for

testing):

a. Disconnect power cord from outlet.

b. Turn unit on its side. Remove the five access screws

located on the bottom of the unit.


c. Then set the unit back down on its base. Place paper

towels on the heater plate to protect it from
scratching. Remove the cowl assembly and lay the
cowl on the heater plate while troubleshooting.

9.4

Replacing Solid State Relays:

a. Avoid miswiring. Examine the terminals carefully and take notes to avoid

miswiring.

b. Remove the plate holding the relay assembly. The nuts holding the relays in place

are easier to reach with the assembly out of the unit.

c. Remove the two nuts holding relays to plate.
d. Apply heat sink compound and install new relay.
e. Reverse this procedure to reinstall.












The cowl assembly is held on by five
screws, which are removed from the
bottom of the unit.

The relays are best replaced by removing the plate
that holds them in place. Two 5/16 nuts hold the
plate in place.

1

2

34

240V

A

C

12A

1

2

34

240V

A

C

12A

Heater plate

relay

Air heater

relay

Heater Plate

Front of HLZ

Advertising
This manual is related to the following products: