Frymaster Heated Landing Zone HLZ 22 User Manual

Page 15

Advertising
background image

Frymaster L.L.C., 8700 Line Avenue 71106, P.O. Box 51000, Shreveport, Louisiana 71135-1000

318-865-1711 FAX 318-862-2394

Printed in the United States Service

Hotline

Page

13

1-800-24-FRYER



9.8 Replacing Hi-limit

a. Follow steps in Accessing plate and air

heaters, 9.7.

b. Remove the shield over the air heater

c. Remove the brace on the left side of the

base assembly, exposing the wire
raceway.

d. Remove the grommets the hi-limit

wiring passes through.

e. Remove the existing hi-limit and pull

wiring through cabinet.

f. Mount the hi-limit on the the spacers,

providing a stand-off from the panel..

g. Push the wires through the raceway

toward the transformer on the controller
side of the HLZ.

h. Slip the wires from the hi-limit into the

area occupied by the transformer.

i. Slip the hi-limit wires into the removed

grommets and snap back into place.

j. Plug the black wire leading from pin 1 in

the computer plug into the terminal of
the hi-limit.

k. Plug the other hi-limit terminal onto the

transformer.

l. Ensure all connections are tight.

m. Retie the wiring assembly

n. Replace the brace, which forms the wire

raceway.

o. Replace the metal shield over the air

heater.

p. Clear away the old adhesive holding the heater plate in place.

q. Put the single-back adhesive in place adhesive-side down and position the heater plate.

r. Ensure the heater plate’s ground wire is reconnected.

s. Plug the 15-pin connector into the computer and replace the controller housing.

t. Reassemble unit as described in step 9.9 below.

The wires for the hi-limit are routed through the hole
used by the RTD wiring. Slip the wires into slot
(shown above) and into the hole.

The wire is routed
from the air
cowling, through
the raceway,
emerging at the
transformer.

Advertising