10 Diagnostic Tests for HLZ

10.1 Relays

The following tests are conducted with
power applied.

Symptom: Air heater or plate heater will not
heat.

Symptom: Air heater or plate heater over
heats. NOTE: Unit will display PROB if
overheated. The probes are producing out of
range resistance. Allow unit to cool before
checking probes.

Tests:

• With power supplied and computer turned on, measure DC voltage across input terminals

of relay. With computer calling for heat ( dot illuminated on display), the reading should be
approximately 12 VDC. Failure to measure DC voltage points to a problem with the
computer or connection.


• With power supplied and computer turned on, measure AC voltage across output

terminals of relay. With computer calling for heat (dot illuminated in display), the reading
should be .6 - .9 VAC. Reading line voltage with the computer calling for heat, indicates a
failure of the computer to supply the necessary DC voltage to close the relay or a failure
of the relay.


10.2 Computer

Symptom: Faulty or no display.

Symptom: No response to buttons.

Tests:

Input power

• With the computer disconnected, check for

12VAC between pins 1 and 3.


Outpu

t

In

put

Outpu

t

In

put

1

2

1

2

3

4

3

4

Viewed from the front of the HLZ, the air heater relay is
nearest the heater plate; the heater plate relay is nearest the
front of the unit.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

The pins in the computer plug are counted bottom to
top, left to right starting with the pin marked by a
protruding ridge.