• Remove power from unit. On 208V units, disconnect black and white wires connecting

blower to heat and latching relays. The resistance between the wires should be between
55 and 65 ohms.


• Remove power from unit. On 240V units, disconnect red and white wires connecting

blower to heat and latching relays. The resistance between the wires should be between
62 and 72 ohms.

10.10 Hi-limit


Symptom:
No display on controller.

Test:

• The hi-limit is in the 12-volt output from the transformer. Remove power from unit.

Disconnect the white braided lead from the wire leading from pin 1 on the computer plug.
Disconnect the white braided lead from the 12-volt side of the transformer. Check
continuity in the hi-limit circuit.

11 Wiring Diagram