FUJITSU MHD2032AT User Manual

Page 104

Advertising
background image

5.3 Host Commands

C141-E050-02EN

5-33

Word

Value

Description

20

X’0000’

Undefined

21

X’0000’

Undefined

22

X’0004’

Number of ECC bytes transferred at READ LONG or
WRITE LONG command

23-26

Firmware revision (ASCII code) *3

27-46

Model name (ASCII code) *4

47

X’8010’

Maximum number of sectors per interrupt on
READ/WRITE MULTIPLE command

48

X’0000’

Reserved

49

X’0B00’

Capabilities *5

50

X’0000’

Reserved

51

X’0200’

PIO data transfer mode *6

52

X’0000’

Reserved

53

X’0007’

Enable/disable setting of words 54-58 and 64-70, 88 *7

54

(Variable)

Number of current Cylinders

55

(Variable)

Number of current Head

56

(Variable)

Number of current sectors per track

57-58

(Variable)

Total number of current sectors

59

*8

Transfer sector count currently set by READ/WRITE
MULTIPLE command *8

60-61

X’60F600’

X’7A2F80’

Total number of user addressable sectors (LBA mode only)

MHC2032AT: X’60F600’
MHC2040AT: X’7A2F80’
MHD2021AT: X’409980’
MHD2032AT: X’60F600’

62

X’0000’

Reserved

63

X’xx07’

Multiword DMA transfer mode *9

64

X’0003’

Advance PIO transfer mode support status *10

65

X’0078’

Minimum multiword DMA transfer cycle time per word :
120 [ns]

66

X’0078’

Manufacturer’s recommended DMA transfer cycle time :
120 [ns]

67

X’00F0’

Minimum PIO transfer cycle time without IORDY flow
control : 240 [ns]

68

X’0078’

Minimum PIO transfer cycle time with IORDY flow control
: 120 [ns]

Advertising
This manual is related to the following products: