FUJITSU MHD2032AT User Manual

Page 115

Advertising
background image

Interface

5-44

C141-E050-02EN

command is used for checking ECC function by combining with the WRITE
LONG command.

Number of ECC bytes to be transferred is fixed to 4 bytes and cannot be changed
by the SET FEATURES command.

The READ LONG command supports only single sector operation.

At command issuance (I/O registers setting contents)

1F7

H

(CM)

0

0

1

0

0

0

1

R

1F6

H

(DH)

×

L

×

DV

Head No. /LBA [MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(FR)

Cylinder No. [MSB] / LBA

Cylinder No. [LSB] / LBA

Sector No. / LBA [LSB]

01

xx

R = 0

with Retry

R = 1

without Retry

At command completion (I/O registers contents to be read)

1F7

H

(ST)

Status information

1F6

H

(DH)

×

L

×

DV

Head No. /LBA [MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(ER)

Cylinder No. [MSB] / LBA

Cylinder No. [LSB] / LBA

Sector No. / LBA [LSB]

00 (*1)

Error information

*1

If the command is terminated due to an error, this register indicates 01.

(18) WRITE LONG (X’32’ or X’33’)

This command operates similarly to the READ SECTOR(S) command except that
the device writes the data and the ECC bytes transferred from the host system to
the disk medium. The device does not generate ECC bytes by itself. The WRITE
LONG command supports only single sector operation.

The number of ECC bytes to be transferred is fixed to 4 bytes and can not be
changed by the SET FEATURES command.