FUJITSU MHD2032AT User Manual

Page 128

Advertising
background image

5.3 Host Commands

C141-E050-02EN

5-57

Table 5.9 Format of insurance failure threshold value data

Byte

Item

00

01

Data format version number

02

Attribute 1

Attribute ID

03

Insurance failure threshold

04 to 0D

Threshold 1
(Threshold of
attribute 1)

Reserved

0E to 169

Threshold 2 to
threshold 30

(The format of each threshold value is the same as
that of bytes 02 to 0D.)

16A to 17B

Reserved

17C to 1FE

Unique to vendor

1FF

Check sum

Data format version number

The data format version number indicates the version number of the data
format of the device attribute values or insurance failure thresholds. The data
format version numbers of the device attribute values and insurance failure
thresholds are the same. When a data format is changed, the data format
version numbers are updated.

Attribute ID

The attribute ID is defined as follows:

Attribute ID

Attribute name

0

(Indicates unused attribute data.)

1

Read error rate

2

Throughput performance

3

Spin up time

4

Start/stop count

5

Re-allocated sector count

7

Seek error rate

8

Seek time performance

9

Power-on time

10

Number of retries made to activate the spindle motor

Advertising